- · Glue applicator RTD has failed
- · Hose RTD has failed
- · Melter RTD has failed
If the hose RTD has failed, the solution is to replace the hose.
If the glue applicator RTD has failed, the solution is to replace the cordset containing the RTD sensor.
If the melter RTD has failed, follow steps below to change RTD sensor.
1.
2.
3. 4. 5.
6.
7. 8. 9. |
Turn main power switch OFF.
Remove electrical enclosure door (332)
and remove melter control connector from AMZ #1 daughter board. Remove temperature sensor (RTD) leads
from connector as shown. Use a 3/8 in. socket to remove four screws (336)
from melter shroud (331) and remove shroud. Remove screw (RS) holding temperature
sensor (RTD) and remove sensor from melter manifold. Pull leads through grommet (13) in the
side of electrical enclosure. Replace new temperature sensor (RTD)
and thread in holding screw (RS). Torque to 7-10 in-lb (0.7-1.0 N•m). Insert sensor leads into side of electrical
enclosure though grommet (13). Tighten temperature sensor leads into connector.
Reconnect connector back into AMZ #1. |
If you need assistance or need parts, please contact us.
800-235-8090